Chapter 9: Monitoring Calls
To monitor calls press: The monitor screen opens.
1. The SIM indicator shows the status of the SIM (see below).
2. The Net indicator shows the status of the SIM registration in the cellular network (see
below).
3. The SIM# indicates the number of the active SIM (1 is local SIM, 2 is SIM Server SIM).
4. The number at the top left indicates the cellular reception level.
5. The Net ID indicates the ID number of the cellular network.
6. The BCCH indicates the number of the Broadcast Channel.
The Net and SIM indicator's States:
·
A red indicator indicates there is no connection.
·
A yellow indicator indicates there is a connection, but no data transfer.
·
A green indicator indicates transfer of data.
Point the mouse on the blue triangle at the bottom right and right-click. A menu will appear:
Refresh port – Get data from the ports.
Reset Port - Reset the ports, cellular port1 and cellular port2.
Port Control – Open the Port Control window.
Chapter 9.1: Port Control Window
This window shows the cellular port status.
It contains:
Status of the port
The IMSI number of the SIM that is registered in the port
The IMEI number of the port
The BCCH cells that the port detect.